Re: PME# Question



Hi Marco,

the question is: Do they have to be reset at all?

Thanks, Lukas

> > Does that mean that for a device supporting PME# from D3cold PME#, the PME
> > Status bit and the PME Enable bit are definitely allowed to have no 
> asynchronous
> > reset (e.g. power on reset)?

> They MUST NOT have async reset driven by the RSTN signal.
> 
> They can, however, be reset at power on, provided that you reset them
> only when VAUX is powered and not when the "normal" 3.3 rail is powered.
> 
> Ciao, Marco.



-------------------------------------------------------------

SysKonnect GmbH             Lukas Reinbold           
                            Senior Hardware Engineer          

Siemensstr. 23              Phone   +49 72 43 502 335
76275 Ettlingen             Fax     +49 72 43 502 365
Germany                     Internet lreinbold@syskonnect.de